Table 1. Mean (±SD) [95% interval confidence] values measured by Jaeger Oxycon Pro (OP) and Jaeger Oxycon Mobile (OM).
Speed
(Km·h-1)
Device VO2
(ml·min-1)
VCO2
(ml·min-1)
VE
(L·min-1)
RER
11 OP 2939 (491)
[2424 - 3454]
2498 (553)
[1917 – 3078]
71.3 (14.9)
[55.7 – 87.0]
.84 (.06)
[.78 - .90]
OM 2616 (220)
[2386 -2847]
2327 (223)
[2093 -2561]
66.4 (6.1)
[60.0 – 72.9]
.89 (.03)
[.86 - .92]
12 OP 3256 (429) *
[2806 - 3706]
2748 (413)
[2315 – 3181]
80 (12)
[68 – 92]
0.84 (0.04) *
[0.81 – 0.88]
OM 2935 (244)
[2679 – 3192]
2755 (254)
[2489 – 3022]
78 (8.0)
[69 – 86]
0.94 (0.03)
[0.91 – 0.97]
13 OP 3537 (442) *
[3074 – 4001]
3023 (427)
[2575 – 3472]
89.0 (14.7)
[73.5 - 104.5]
0.85 (0.04) *
[0.81 - 0.90]
OM 3175 (214)
[2950 – 3399]
3102 (223)
[2868 – 3337]
89.7 (9.0)
[80.3 - 99.1 ]
0.98 (0.03)
[0.94 – 1.01]
14 OP 3832 (439) *
[3371 – 4293]
3340 (443)
[2875 – 3805]
99.3 (18.0)
[80.4 – 118.3]
0.87 (0.04)*
[0.83 – 0.91]
OM 3400 (234)
[3154 – 3646]
3424 (265)
[3146 – 3703]
101.5 (12.6)
[88.3 - 114.7]
1.01 (0.03)
[0.97 – 1.04]
15 OP 4195 (392)*
[3783 – 4606]
3575 (416)
[3322 - 4194]
112.5 (19.1)
[92.4 – 132.6]
0.90 (0.05)*
[0.85 – 0.94]
OM 3656 (254)
[3390 - 3923]
3794 (358)
[3418 - 4170]
112.2 (18.5)
[94.8 -129.5 ]
1.04 (0.04)
[0.99 – 1.09]
16 OP 4429 (385)*
[4025 – 4833]
4128 (422)
[3685 -4570 ]
124.5 (20.9)
[102.6–146.4]
0.93 (0.05)
[0.88 – 0.99]
OM 3892 (296)
[3581 - 4202]
4180 (467)
[3689 - 4670]
123.3 (20.9)
[101.4–145.3]
1.07 (0.07)
[0.99 – 1.15]
17 OP 4580 (376)*
[4113 – 5048]
4435 (485)
[3833 – 5037]
136.2 (22.4)
[108.4–164.0]
0.97 (0.06)*
[0.89 – 1.04]
OM 3966 (272)
[3268 - 4304]
4497 (394)
[4008 - 4986]
141.8 (16.5)
[121.3–162.3]
1.14 (0.05)
[1.08–1.20]
VO= oxygen consumption, VCO= Production of CO, V = ventilation volume, RER = respiratory exchange ratio * significant differences (p < 0.05).