Table 1 Values of mean flight time as measured by the high velocity cameras (HSC), the force platform synchronized with the linear position transducer (FP+LPT) and the ™ system; and values of mean velocity at takeoff as measured by the FP+LPT and the™ system. Pearson correlation coefficients (r), paired sample Student’s t-test; and probable values (p-value) are also presented.
|
HSC mean (SD) |
FP + LPT mean (SD) |
Keimove™ mean (SD) |
Pearson correlation r (p-value) |
Student’s t-test t (p-value) |
|
|
|
|
HSC - Keimove™ |
FP+LPT – Keimove™ |
HSC - Keimove™ |
FP+LPT – Keimove™ |
Flight Time (ms) |
421.0 (21.4) |
422.3 (24.3) |
418.8 (19.1) |
.989 (.001) |
.989 (.001) |
.969 (.341) |
1.369 (.184) |
Velocity at takeoff (m·s-1) |
--- |
3.196 (.114) |
3.215 (.104) |
--- |
.895 (.001) |
--- |
1.906 (.064) |