Table 1. HRV changes when editing RR intervals from a set of 51 orthostatic tests. Percentages compared to the original artifact-free recordings. Values are mean ± SD [min max].
|
RMSSD, % |
SDNN, % |
LF, % |
HF, % |
Tot, % |
supine |
rand10 |
0 ± 0 [-1 1] |
0 ± 0 [0 1] |
-1 ± 0 [-2 1] |
0 ± 1 [-3 4] |
0 ± 0 [-1 1] |
rand30 |
0 ± 0 [-1 2] |
0 ± 0 [-1 1] |
0 ± 1 [-3 4] |
1 ± 1 [-4 7] |
0 ± 1 [-3 3] |
rand50 |
0 ± 0 [-1 2] |
-1 ± 0 [-2 0] |
-1 ± 1 [-6 4] |
2 ± 1 [-2 6] |
-1 ± 1 [-5 2] |
rand100 |
1 ± 0 [-1 3] |
0 ± 0 [-1 2] |
6 ± 12 [-3 337]* |
-1 ± 2 [-8 14] |
5 ± 18 [-4 668]* |
artifact |
413 ± 2 [403 422]* |
54 ± 0 [54 54]* |
0 ± 1 [-1 7] |
-1 ± 1 [-3 3] |
+1 ± 1 [0 4] |
standing |
rand10 |
0 ± 0 [-1 1] |
0 ± 0 [0 1] |
1 ± 0 [-1 2] |
-1 ± 1 [-4 3] |
0 ± 0 [-1 2] |
rand30 |
0 ± 0 [-2 1] |
0 ± 0 [-1 1] |
-1 ± 1 [-4 3] |
-1 ± 1 [-6 3] |
-1 ± 1 [-3 2] |
rand50 |
0 ± 0 [-1 2] |
0 ± 1 [-1 1] |
2 ± 1 [-3 4] |
2 ± 1 [-3 6] |
1 ± 1 [-2 5] |
rand100 |
0 ± 0 [-1 2] |
0 ± 0 [-1 1] |
4 ± 13 [-5 441]* |
2 ± 2 [-4 28] |
5 ± 21 [-4 562]* |
artifact |
269 ± 1 [264 272]* |
47 ± 0 [47 47]* |
1 ± 1 [0 8] |
-1 ± 0 [-2 2] |
0 ± 1 [0 9] |
rand10 rand30 rand50 and rand100: randomly adding or subtracting 10, 30, 50 and 100ms to each RR interval; artifact: systematically adding a short-long sequence in each position possible in the RR times series.* p < 0.05 compared to the raw artifact-free trace.