Table 5 Clean heart rate (b·min) and breathing frequency (br·min) data at 10 and 12 km·h.
Velocity Descriptive Data Validity Data (Log)
Predicted
M ± S
Criterion
M ± S
Mean Bias
±95% CI
Mean Bias
±95% LoA
PCC
r
CoD
r2
Heart rate
10 km·h-1 159.6 ± 21.4 160.0 ± 20.6 -.45 ± .75 .40 ± 7.70 .96* 92%
12 km·h-1 174.3 ± 20.4 176.0 ± 19.1 -1.64 ± .89 -1.00 ± 7.40 .95* 90%
All data 122.2 ± 38.1 122.8 ± 38.2 -.65 ± .26 -.60 ± 8.88 .99* 96%
Breathing Fr
10 km·h-1 30.4 ± 5.3 31.6 ± 7.0 -1.27 ± .51 -3.20 ± 23.90 .86* 75%
12 km·h-1 34.6 ± 5.4 37.8 ± 5.4 -3.14 ± .61 -7.40 ± 23.50 .86* 75%
All data 24.4 ± 8.4 25.3 ± 10.4 -.84 ± .22 -.60 ± 33.99 .94* 88%
* p < 0.01Tabular report of validity statistics: Descriptive statistics, Standard Deviation (S), Mean Bias, 95% Confidence Intervals (CI), Log transformed mean bias, 95% Limits of Agreement (LoA), Pearson’s Product Correlation Coefficient (PCC) and Coefficient of Determination (CoD) across whole data set.