Research article - (2007)06, 93 - 97 |
Strength Performance Assessment in a Simulated Men’s Gymnastics Still Rings Cross |
Jennifer K. Dunlavy1, William A. Sands1,, Jeni R. McNeal2, Michael H. Stone3, Sarah L. Smith1, Monem Jemni4, G. Gregory Haff5 |
Key words: Portable force platform, field test |
Key Points |
|
|
|
Approach to the Problem |
Through the use of two portable FPs, two groups of athletes (performers and non-performers), attempted a simulated still rings cross position. The two small FPs were first tested for reliability and validity; having met these criteria, they were then used to measure the vertical forces applied by the gymnasts in a simulated cross. The force-time records were then compared to body weight to determine how closely the gymnasts came to achieving forces equal to body weight and thus the ability to perform the cross. |
Subjects |
Ten male gymnasts (n = 5 age group level gymnasts and n = 5 Senior US National Team members) volunteered to participate in this study. Appropriate informed consent in writing was obtained in compliance with U.S. Olympic Committee requirements. The characteristics of the athletes are shown in |
Instrumentation |
The force platforms (Pasco Scientific, Inc. Roseville, CA, USA, PS-2141) were new to our laboratory and were thus tested for reliability and validity via three methods (Cheetham and Mizoguchi, The first method of calibration/validation assessed the linearity of the force values from the FP. Eleven static weight values, ranging from 244.5 N to 2449.0 N, were placed in the center of the FP. The force output values collected from the FP were correlated to the actual weight values from the previously weighed weight plates used as the calibrated resistances. The correlations for both plates were sufficiently high to indicate linearity of response (both FPs r values = 0.999, both standard errors of estimate <1.5 N). The second method of FP validation determined whether areas of the surface of the FP suffered from regional dependencies. This test consisted of placing a wooden block (8.5 cm x 9.0 cm x 1.7 cm) in nine randomly ordered positions on the surface of the FP. The nine positions included each corner, the center of each edge, and the center of the FP. At each position, a 243.7 N (24.84 kg) weight plate was placed on top of the wooden block. Fifty raw samples were recorded at 100 Hz at each position. The data were then analyzed using two Oneway Analyses of Variance (ANOVA) assessing regional differences by selected positions on the FP. The ANOVAs and post hoc Tukey HSD procedures revealed that there were statistically significant differences between all regions of FP1 and all regions except one pair in FP2 (FP1, F(8,377) = 8975.2, p < 0.001; FP2, F(8,377) = 15492.6, p <0.001). However, in spite of the statistical differences, the means of each region ranged from 241.2 to 244.5 N on FP1 and 239.6 to 245.3 N on FP2. Moreover, the coefficients of variation ranged from 0.00030 to 0.00042 for FP1 and 0.00032 to 0.00049 for FP2. Thus, the absolute differences between regions, although statistically different, showed low variability and were small in absolute terms (i.e., approximately three to six Newtons). The third method consisted of placing the portable FP on top of a larger (90 cm x 60 cm x 16 cm) calibrated Kistler (Kistler Instruments Corp, Amherst, NY, USA) FP mounted in the laboratory floor. Simultaneous force data were collected from both FPs at a sampling rate of 1000 Hz during three separate static jumps. Vertical ground reaction forces from the Kistler FP were analyzed using Peak Motus software (Peak Performance Technologies, Inc., Centennial, CO, USA, Version 9.1) and compared to data from the portable FPs. Force-time curves were then overlaid and correlated to determine the strength of a linear relationship between the two types of plates. The correlations over the three trials for both FPs ranged from r = 0.994 to r = 0.999, with standard errors of estimate ranging from 6.6 to 61.5 N). The results from the three calibration tests showed that the FPs were valid and reasonably linear; therefore the data obtained when testing the athletes were presumed to be accurate in representing ground reaction forces and when comparing one set of forces from one FP to the other. |
Simulated cross testing procedures |
Athletes were positioned standing between two solid gymnastics spotting blocks (60 x 60 x 120 cm). The two FPs were placed on top of each block with a single piece of 1.27 cm (0.5”) plywood between the mat and the FP to create a flat surface. The distance between the two mats was adjusted to accommodate differing arm lengths of the gymnasts. A small wooden block (12.5 cm x 9 cm x 3.5 cm) was placed on the center of each FP to eliminate assistance from the gymnasts’ forearms due to contact with support of the forearms on the FP. Each athlete attempted to press downward onto the FP in the simulated cross position and elevate himself off the floor, holding for three or more seconds. Two trials were performed by each athlete. A completed cross was one in which the athlete was able to lift himself off the ground while keeping the arms parallel to the ground, abducted at shoulder height ( |
Statistical analyses |
Athletes were grouped for analysis purposes based on whether or not they were able to perform a cross on the rings in competition (Performer versus Non-Performer). For each athlete, the single arm forces as measured by the portable FPs were combined to create a summed force trial. A mean value was determined by visual inspection of the force-time curve and identification of one second of relatively stable (by visual inspection of the force-time curve) force production at or near the peak force value. A peak force value was determined by extracting the highest force value during the period of relatively stable force production. Stable force production was considered to be a period of at least one second. The summed arm forces were also compared to body weight through simple subtraction (i.e., the mean of the summed arm forces was subtracted from body weight, and the peak of the summed arm forces was subtracted from body weight). Stability/reliability of the trials data was determined using an intraclass correlation coefficient and a t-test to assess a statistical difference between trials. Reliability analyses of trials data were performed using the methods outlined by Hopkins (a new view of statistics, Internet Society for Sport Science, http://www.sportsci.org/resource/stats/). The mean of the trials data was then used for further analyses (Henry, |
|
|
The trials data showed high stability/reliability (intraclass correlation mean of summed arm forces 0.99, and mean of peak arm forces 0.99). No statistically significant difference between trials for either variable was observed, p > 0.05. |
|
|
The data obtained from this study showed that through the use of two portable FPs, stable/reliable data on the gymnastics cross could be obtained. The results also indicated that the FPs could provide information of sufficient fidelity to distinguish between athletes who could perform the cross from those who could not. In spite of a computer-based literature search on “cross ”and “still rings, ”only a few studies could be located. None of the studies dealt with the measurement of forces exerted by the athlete in the cross position. One needs to go back to 1985 to find a lay article on learning a cross, but with no indication of how to measure progress (Hesson, As shown in Future research using this simulated cross approach should also include an electromyographic analysis. Moreover, future investigations should include longitudinal assessment of the progress of the gymnast in learning to determine if the force-time data from a simulated cross using portable FPs can predict when the gymnast will be able to summon the strength and skill to perform a real cross on the still rings for the first time. |
|
|
Skill simulators, especially those that also provide measurement, can be useful to coaches and athletes in training and assessment of progress. The small portable force platforms described here appear to be useful for determining the progress of a gymnastics still rings cross. |