Research article - (2009)08, 344 - 351
Quantification of the Impaired Cardiac Output Response to Exercise in Heart Failure: Application of a Non-Invasive Device
Jonathan Myers1,, Pradeep Gujja2, Suresh Neelagaru3, Leon Hsu1, Daniel Burkhoff4
1Veterans Affairs Palo Alto Health Care System and Stanford University, Palo Alto, CA
2Texas Tech University of Health Sciences, Amarillo, Texas
3Lonestar Arrythmia and Heart Failure Center, Amarillo, Texas
4Columbia University, New York, USA

Jonathan Myers
✉ VA Palo Alto Health Care System, Cardiology Division - 111C 3801 Miranda Ave., Palo Alto, CA 94304, USA
Email: drj993@aol.com
Received: 05-03-2009 -- Accepted: 11-05-2009
Published (online): 01-09-2009

ABSTRACT

An impaired cardiac output (CO) response to exercise is a hallmark of chronic heart failure (CHF), and the degree to which CO is impaired is related to the severity of CHF and prognosis. However, practical methods for obtaining cardiac output during exercise are lacking, and what constitutes and impaired response is unclear. Forty six CHF patients and 13 normal subjects underwent cardiopulmonary exercise testing (CPX) while CO and other hemodynamic measurements at rest and during exercise were obtained using a novel, non-invasive, bioreactance device based on assessment of relative phase shifts of electric currents injected across the thorax, heart rate and ventricular ejection time. An abnormal cardiac output response to exercise was defined as achieving ≤ 95% of the confidence limits of the slope of the relationship between CO and oxygen uptake (VO2). An impaired CO slope identified patients with more severe CHF as evidenced by a lower peak VO2, lower peak CO, heightened VE/VCO2 slope, and lower oxygen uptake efficiency slope. CO can be estimated during exercise using a novel bioreactance technique; patients with an impaired response to exercise exhibit reduced exercise capacity and inefficient ventilation typical of more severe CHF. Non- invasive measurement of cardiac performance in response to exercise provides a simple method of identifying patients with more severe CHF and may complement the CPX in identifying CHF patients at high risk.

Key words: Heart failure, cardiac output, oxygen uptake, exercise testing

Key Points
  • Non-invasive measurement of cardiac output during exercise is feasible in patients with heart failure.
  • Impairment in the CO response to exercise identifies heart failure patients with more severe disease, lower exercise capacity and inefficient ventilation.
  • Non-invasive measurement of cardiac performance during exercise has potentially important applications for the functional and prognostic assessment of patients with heart failure.
INTRODUCTION

The cardiopulmonary exercise test (CPX) has been widely used over the last two decades in the management of patients with chronic heart failure (CHF). Its applications include classifying the severity of disease, evaluating the effects of therapy, estimating prognosis, and developing a safe and effective exercise prescription (Arena et al., 2007; Myers, 2005). In particular, a large number of studies have been published related to the prognostic applications of the CPX. Directly measured maximal oxygen uptake (peak VO2) has been an important medium for estimating risk in patients with CHF because it closely parallels the cardiac output (CO) response to exercise (Pina et al., 2003). However, peak VO2 can be difficult to determine in some patients (Myers, 1996; Noakes, 1998), can be difficult to define (Myers et al., 1989; Myers, 1996; Noakes, 1998), is influenced by motivation, and varies considerably in some patients with similar cardiac function (Myers et al., 2006; Wilson et al., 1995a; 1995b; 1999). For example, Wilson and colleagues (Wilson et al., 1995a; 1995b; 1999) reported dissociations between exertional symptoms, peak VO2, and circulatory function in patients with CHF. Chomsky and colleagues (Chomsky et al., 1996) observed that the CO response to exercise was a stronger predictor of survival than peak VO2 among cardiac transplant candidates. These and other investigations (Lang et al., 2007; Metra et al., 1999; Williams et al., 2001; 2005) have therefore suggested that the CO response to exercise should be quantified when assessing the degree of cardiac dysfunction or when estimating risk in patients with CHF.

However, drawbacks to the routine measurement of CO include the fact that it is invasive, time consuming, carries an inherent risk, is not always accurate, is expensive, and is particularly difficult to measure during exercise. Thus, it is impractical for routine clinical use. For these reasons, a non- invasive and easily applied method to quantify CO and other hemodynamic indices during exercise would have important applications for the routine clinical evaluation of CHF patients. While a number of non-invasive approaches have been proposed and acceptable agreement with the direct Fick, thermodilution or other techniques have been reported at rest (Leslien et al., 2004; Newman and Callister, 1999; Remmen et al., 2002; Thomas and Popovic, 2006), few previous studies have validated non-invasive estimates of cardiac output during exercise in patients with CHF. One novel approach that has recently undergone validation involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. This differs from the bioimpedance approach, which relies on detection of flow-dependent changes in electrical signal amplitude, which are inherently more difficult to detect and more subject to noise. Accordingly, this approach (termed “bioreactance”) has an improved signal-to-noise ratio and is less susceptible to physical factors such as body habitus, body motion and ambient conditions (Keren et al., 2007). The accuracy and precision of this technique has been demonstrated previously in comparison to invasive measurements with thermodilution (Raval et al., 2008; Squara et al., 2007).

The ability to easily identify CHF patients with an abnormal cardiac output response to exercise would be useful in order to better classify the degree of exercise impairment, the severity of disease, and to estimate risk. The purposes of the current study were: 1) to propose a measurement standard for using such a device when classifying the degree of hemodynamic impairment in CHF; and 2) to determine the association between this response and CHF severity based on other clinical and CPX responses.

METHODS
Subjects

This was a retrospective analysis of data obtained from 59 consecutive subjects referred to a private cardiology clinic for CPX testing for evaluation of dyspnea. All subjects provided written consent for the use of their data in the analysis. Forty six of the subjects had heart failure (27 with low EF, 19 with normal EF) and 13 were ultimately diagnosed as normal (normal EF and peak VO2, dyspnea based on noncardiac factors). Demographic and clinical characteristics of the subjects are summarized in Table 1. In the overall population there was a broad range of EFs, peak VO2 and peak CO values. All subjects were limited during exercise by fatigue or dyspnea, and none had clinical evidence of pulmonary disease or ischemic changes on the ECG.

Exercise testing

Symptom limited maximal exercise tests were performed on a treadmill using a ramp protocol (Myers et al., 1991). All subjects were requested to abstain from eating or smoking at least 3 hours prior to the test. Ventilatory oxygen uptake was measured using a Medical Graphics Corporation system (CPX-D, St. Paul, MN). Gas exchange data were acquired breath-by-breath and expressed in ten second intervals of rolling 30 second averages. Oxygen uptake, carbon dioxide production, minute ventilation, and respiratory exchange ratio were calculated on-line. The percentage of age-predicted normal peak VO2 was determined for each patient using the equation of Wasserman et al. (Wasserman et al., 2004). Estimated metabolic equivalents (METs) were determined from the American College of Sports Medicine equations (American College of Sports Medicine, 2009). A 12-lead electrocardiogram was monitored continuously and recorded every minute. Blood pressure was recorded manually every two minutes throughout the test. All subjects were encouraged to provide a maximal effort; among patients with CHF, the Borg 0 to 10 perceived exertion scale was used to quantify effort (Borg, 1998).

The ventilatory threshold was determined by two experienced, independent reviewers using the V-slope method (Beaver et al., 1986) and confirmed by ventilatory criteria. VE and VCO2 responses, acquired from the initiation of exercise to peak, were used to calculate the VE/VCO2 slope via least squares linear regression (y = mx + b, m = slope) (Arena et al., 2007). The oxygen uptake efficiency slope (OUES) was derived by the slope of a semi-log plot of minute ventilation versus VO2 from rest to peak exercise. As such, the OUES is an estimation of the efficiency of ventilation with respect to VO2, with greater slopes indicating greater ventilatory efficiency (Arena et al., 2007).

Cardiac output

The NICOM bioreactance-based system (Cheetah Medical, Wilmington, Delaware) is based on an analysis of relative phase shifts of an oscillating current that occur when traversing the thoracic cavity. This contrasts with the traditional bioimpedance-based systems which rely only on measured changes in signal amplitude. The NICOM system is comprised of a radiofrequency generator for creating a high frequency current that is injected across the thorax, 4 dual surface electrodes that are used to establish electrical contact with the body, a receiving amplifier for recording the transthoracic voltage in response to the injected current and circuitry for determining the relative phase shift between the injected current and the recorded voltage. Within each of the dual electrodes, one electrode is used by the high frequency current generator, while the other is used by the input voltage amplifier. Signals are applied to and recorded from the left and right sides of the thorax; these signals are processed separately and averaged after digital processing. During exercise testing, the electrodes can be placed on the subject’s back so that the cables do not interfere with upper body motion.

The signal processing unit of the system determines the relative phase shift (∆Ф) between the input signal relative to the output signal. ∆Ф in turn is due to changes in blood flow in the aorta. It has been shown that stroke volume (SV) is estimated by:

Statistical analysis

Descriptive statistics are presented as mean (±SD). The associations between non-invasive CO data, clinical variables, and other exercise test responses were assessed using linear regression. The adequacy of the cardiac output response to exercise was assessed by quantifying the minute-by-minute slope of the linear relation between CO and oxygen uptake. A patient achieving ≤ 95% of the confidence limits of the slope of this relationship (slope ≤ 0.09) was considered to have an abnormal CO response to exercise. Comparisons between normal subjects and CHF patients with normal and abnormal cardiac output responses to exercise were performed using one-way ANOVA. Post-hoc testing was performed using the Bonferroni method.

RESULTS

Eleven of the patients with CHF had an abnormal CO response to exercise. Table 2 shows resting and peak exercise CO, cardiac index, peak aortic flow (Dx/dt), and ventricular ejection time (VET) between normal subjects and CHF patients with normal and abnormal CO responses to exercise. Resting cardiac index was higher in CHF patients with an abnormal CO response to exercise vs. CHF patients with a normal response (p < 0.05). However, while peak exercise CO and cardiac index were similar between normal subjects and CHF patients with a normal CO response to exercise (peak CO 20.0 ± 10 and 19.7 ± 6.5 l·min-1, respectively), they were lower among patients with an abnormal CO response to exercise (peak CO 11.1 ± 4.4 l·min-1, p < 0.001 between groups). Arterio-venous (a-VO2) oxygen difference at peak exercise was wider in patients with an abnormal CO response to exercise vs. those with a normal CO response (12.0 ± 3.8 vs. 8.7 ± 3.3 ml/100 ml, p < 0.05).

Exercise test responses among normal subjects, those with CHF and a normal CO response, and CHF patients with an impaired CO response are summarized in Table 3. For the overall group, the mean maximal perceived exertion was 7.8 ± 1.7 (range 5-10), and the mean peak respiratory exchange ratio was 1.12 ± 0.09 (range 0.87-1.28), suggesting that maximal effort was achieved by most patients. Normal subjects generally achieved higher exercise test responses than both groups of patients with CHF. Mean maximal oxygen uptake values for normal subjects and patients with a normal and abnormal CO response were 24.8 ± 6.0, 16.8 ± 6.0, and 14.1 ± 6.0 ml·kg-1·min-1, respectively (p < 0.001). Similarly, oxygen uptake at the ventilatory threshold was highest among normal subjects and lowest among CHF patients with an impaired CO response to exercise. Relative to both normal subjects and the subgroup of patients with a normal CO response, peak VO2 expressed in ml·min-1 was lower among CHF patients with an abnormal CO response to exercise (1857 ± 464, 1494 ± 518, and 1169 ± 628 ml·min-1, respectively, p < 0.001). CHF patients with an abnormal CO response to exercise also had a higher VE/VCO2 slope and tended to have a lower OUES vs. patients with a normal CO response.

Figure 1 illustrates the relationship between changes in CO and VO2 during exercise in normal subjects and patients with CHF, expressed as group means each minute. In both groups, these two responses were closely related (r = 0.81 for CHF and r = 0.78 for normal subjects, p < 0.001 for both). Table 4 presents correlation coefficients between CO slope, cardiac performance measures at peak exercise, and CPX responses in patients with CHF and normal subjects. The CO slope was significantly related to peak VO2 in patients with CHF (r = 0.51, p < 0.001) and was significantly related to peak CO in both groups (r = 0.48, p < 0.001 and 0.79, p = 0.002 for CHF and normal subjects, respectively).

DISCUSSION

In the present study we sought to better define a normal standard when using a novel non-invasive device for classifying the degree of exercise impairment and stratifying risk in patients with CHF. Because the measurement of cardiac performance has been suggested to be an important complement to peak VO2 and other CPX responses when assessing circulatory dysfunction and stratifying risk in CHF (Chomsky et al., 1996, Lang et al., 2007, Metra et al., 1999, Williams et al., 2001, Williams et al., 2005, Wilson et al., 1995a), the ability to acquire such data easily and without the need for arterial or mixed venous blood sampling potentially has a great deal of value for both clinical and research applications in these patients.

The accuracy of the NICOM device to measure cardiac output noninvasively as compared to thermodilution has been demonstrated in two prior studies (Raval et al., 2008; Squara et al., 2007). These studies compared invasive and NICOM-based measurements of CO over long periods of time (up to 24 hours), in varied clinical settings and spanning wide ranges of CO values. Results of two other studies (Maurer et al., 2009; Myers et al., 2007) have reported a tight relationship between VO2 and CO during exercise using this method that are similar to those reported in earlier studies. Hemodynamic measurements derived from the device have also identified NYHA class-dependent abnormalities during exercise that are consistent with prior studies using invasive methods (Maurer et al., 2009). The validity of the NICOM device is further suggested by the present data showing a close relationship between the change in VO2 and CO throughout exercise (r = 0.83, p < 0.001). This close association is well-established in the literature and is typical of previous studies using directly-measured CO (Damato et al., 1966, Lewis et al., 1983, Myers et al., 1991, Wilmore and Costill, 1999). In addition, the resting and peak exercise values for CO and other hemodynamic responses fell within the expected range for normal subjects and patients with CHF (Table 2).

We observed that patients with more severe disease, those with more inefficient ventilation, and those with a lower exercise capacity generally had worse ventricular performance during exercise (reduced slope of the relationship between VO2 and CO, lower peak CO) as estimated by the bioreactance technology. Whereas CHF patients with a normal CO response to exercise had a peak CO that was similar to normal subjects (both approximately 20 l·min-1), subjects with an impaired CO slope during exercise had a peak CO that was reduced by nearly 50%. The importance of an impaired CO response to exercise emphasized by studies measuring CO directly has been based in part on the fact that resting cardiac function and even peak VO2 can be similar among subjects who differ markedly in their cardiac performance during exercise (Chomsky et al., 1996; Lang et al., 2007; Metra et al., 1999; Wilson et al., 1995a; 1995b). Our observations confirm this in that patients with an impaired CO response to exercise actually had resting CO values that were higher than those in patients with a normal CO response to exercise. In addition, similar to the findings of Wilson et al (Wilson et al., 1995a), cardiac impairment in response to exercise was only modestly related to peak VO2 (Table 4). This underscores the concept that identifying patients who have an impaired hemodynamic response to exercise is clinically relevant independent of resting cardiac function and peak VO2 (Chomsky et al., 1996; Lang et al., 2007; Metra et al., 1999; Wilson et al., 1995a; 1995b).

There are a number of clinical implications related to a valid non-invasive measure of cardiac performance during exercise. First, guidelines on risk stratification in CHF have traditionally focused on resting hemodynamic measurements, but resting measures have tended to be inadequate predictors of risk (Chomsky et al., 1996; Metra et al., 1999; Myers and Gullestad, 1998; Myers et al., 1998). Thus, the addition of exercise hemodynamic responses to the risk paradigm in CHF, in addition to CPX responses, will likely increase the predictive value of risk models (Chomsky et al., 1996; Metra et al., 1999), although this has not been a universal finding (Aaronson et al., 1997; Myers and Gullestad, 1998). Second, the cardiac output response to exercise has been shown to be an even more powerful prognostic marker than peak VO2, and estimates of risk appear to be optimized when these two responses are combined (Cotter et al., 2003; Metra et al., 1999; Williams et al., 2001; 2005). Third, despite the widely-recognized importance of ventilatory gas exchange techniques in patients with CHF (Arena et al., 2007; Myers, 2005), surveys have shown that the vast majority of clinical exercise testing is done without them (Myers et al., 2000). Thus, the use of non-invasive CO may be particularly useful when ventilatory gas exchange techniques are not available. Finally, the technique is non-invasive, inexpensive, and is not burdensome for the patient or user. Thus, the addition of non-invasive indices of cardiac performance to the standard exercise test has the potential to better quantify cardiac dysfunction and estimate risk in patients routinely evaluated for CHF.

An important consideration in our analysis was how best to establish what constitutes a normal and impaired response in order to classify patients appropriately, since there are few such data in the literature with which to compare. While there have been a number of efforts using invasive techniques to determine the appropriate CO response to upright exercise and its confidence limits (Damato al., 1996; Higginbotham et al., 1983; Julius et al., 1967; Rowell, 1986), these have generally been limited to normal subjects and it is unclear what an appropriate response and the variance of CO is among patients with CHF. We chose to use the slope of the relationship between CO and VO2 since it reflects the capacity of CO to increase in accordance with physiologic work. We defined an impaired response as a slope that fell below the 95% confidence limits of normal. Similar approaches have been used to study O2 kinetics in response to exercise (Myers et al., 1991; Porszasz et al., 2003; Tamesis et al., 1993), and it has been demonstrated that patients with CHF have a marked impairment in O2 kinetics compared to normal subjects and those with coronary disease (Myers et al., 1991). Intuitively, patients with more severe CHF will have the most impaired increase in CO (a lower slope), and it is well-known that such patients compensate for an inadequate CO response to exercise by a widening of the a-VO2 difference (Myers and Froelicher, 1991; Sullivan et al., 1989), as we observed in the current study. While the approach we employed was empirical, it provided a marked distinction between normal subjects and CHF patients with and without an impaired CO response to exercise. Further refinement of methods to define this response will likely need to consider age, type of heart failure, gender, and its association with risk for future adverse events.

Limitations

As mentioned above, the estimation we used to define the adequacy of the CO response to exercise was empirical; there may be other methods with which to express this response. In addition, there are other methods of estimating cardiac output, including CO2 rebreathing and inert gas rebreathing methods (Lang et al., 2007); the adequacy of the CO response to exercise in CHF using these methods has not been fully explored. The application of the bioreactance device must be further validated by direct measurements of CO, and among populations of patients with varying degrees of CHF. Our approach focused on the central hemodynamic response to exercise, but peripheral factors also play an important role in determining exercise tolerance in CHF, and these must also be considered when using the exercise response to make clinical judgments in CHF.

CONCLUSION

An impairment in the CO response to exercise using a novel non-invasive technique identified CHF patients with more severe disease, lower exercise capacity and inefficient ventilation, and thus provided added insight into the cardiovascular status of patients with CHF. Non-invasive measurement of cardiac performance in response to exercise has potentially important applications for the functional and prognostic assessment of patients with CHF.

AUTHOR BIOGRAPHY
     
 
Jonathan Myers
 
Employment:Health Research Scientist.
 
Degree: PhD
 
Research interests: Exercise Physiology.
  E-mail: drj993@aol.com
   
   

     
 
Pradeep Gujja
 
Employment:Cardiologist.
 
Degree: MD
 
Research interests: Heart Failure
  E-mail:
   
   

     
 
Suresh Neelagaru
 
Employment:Cardiologist.
 
Degree: MD
 
Research interests: Heart Failure/Arrhythmias.
  E-mail:
   
   

     
 
Leon Hsu
 
Employment:Medical Student.
 
Degree: BS
 
Research interests: Exercise Physiology.
  E-mail:
   
   

     
 
Daniel Burkhoff
 
Employment:Cardiologist.
 
Degree: MD
 
Research interests: Heart Failure
  E-mail:
   
   

REFERENCES
Aaronson K.D., Schwartz J.S., Chen T.M., Wong K.L., Goin J.E., Mancini D.M. (1997) Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation. Circulation 95, 2660-2667.
American College of Sports Medicine. (2009) Guidelines on Exercise Testing and Prescription. Baltimore. Lippincott, Williams & Wilkins.
Arena R., Guazzi M., Myers J. (2007) Ventilatory abnormalities during exercise in heart failure: A mini review. Current Respiratory Medicine Reviews 3, 179-187.
Beaver W.L., Wasserman K., Whipp B.J. (1986) A new method for detecting the anaerobic threshold by gas exchange. Journal of Applied Physiology 60, 2020-2027.
Borg G.A.V. (1998) Borg’s perceived exertion scales. Champaign. Human Kinetics.
Chomsky D.B., Lang C.C., Rayos G.H., Shyr Y., Yeoh T.K., Pierson R.N., Davis S.F., Wilson J.R. (1996) Hemodynamic exercise testing: A valuable tool in the selection of cardiac transplantation candidates. Circulation 94, 3176-3183.
Cotter G, Williams SG, Vered Z, Tan LB. (2003) Role of cardiac power in heart failure. Current Opinion in Cardiology 18, 215-222.
Damato A.N., Galante J.G., Smith W.M. (1966) Hemodynamic response to treadmill exercise in normal subjects. Journal of Applied Physiology 21, 959-966.
Higginbotham M.B., Morris K.G., Conn E.H., Coleman R.E., Cobb F.R. (1983) Determinants of variable exercise performance among patients with severe left ventricular dysfunction. American Journal of Cardiology 51, 52-60.
Julius S., Amery A., Whitlock L.S., Conway J. (1967) Influence of age on the hemodynamic response to exercise. Circulation 36, 222-230.
Keren H., Burkhoff D., Squara P. (2007) Evaluation of a non-invasive cardiac output monitoring system based on thoracic bioreactance. American Journal of Physiology – Heart and Circulatory Physiology 293, H583-589.
Lang C.C., Agostoni P., Mancini D.M. (2007) Prognostic significance and measurement of exercise-derived hemodynamic variables in patients with heart failure. Journal of Cardiac Failure 13, 672-679.
Leslien S., McKee S., Newby D., Webb D., Denvir M. (2004) Non-invasive measurement of cardiac output in patients with chronic heart falure. Blood Pressure Monitoring 9, 277-280.
Lewis S.F., Taylor W.F., Graham R.M., Pettinger W.A., Schutte J.E., Blomqvist C.G. (1983) Cardiovascular responses to exercise as functions of absolute and relative workload. Journal of Applied Physiology 54, 1314-1323.
Maurer M.M., Burkhoff D., Maybaum S., Franco V., Vittorio T.J., Williams P., White L., Kamalakkannan G., Myers J., Mancini D. (2009) Exercise cardiac output provides important information in the evaluation of heart failure patients: A multicenter study of non-invasive cardiac output by bioreactance during symptom-limited exercise. Journal of Cardiac Failure , -.
Metra M, Faggiano P., D’Aloia A., Nodari S., Gualeni A., Raccagni D., Dei Cas L. (1999) Use of cardiopulmonary exercise testing with hemodynamic monitoring in the prognostic assessment of ambulatory patients with chronic heart failure. Journal of the American College of Cardiology 33, 943-950.
Myers J. (1996) Essentials of Cardiopulmonary Exercise Testing. Champaign. Human Kinetics.
Myers J. (2005) Applications of cardiopulmonary exercise testing in the management of cardiovascular and pulmonary disease. International Journal of Sports Medicine 26, s490-s55.
Myers J., Buchanan N., Walsh D., Kraemer M., McAuley P., Hamilton-Wessler M., Froelicher V.F. (1991) Comparison of the ramp versus standard exercise protocols. Journal of the American College of Cardiology 17, 1334-1342.
Myers J., Froelicher V.F. (1991) Hemodynamic determinants of exercise capacity in chronic heart failure. Annals of Internal Medicine 115, 377-386.
Myers J., Gujja P., Neelagaru S., Keren H., Burkhoff D. (2007) Cardiac output and cardiopulmonary responses to exercise in heart failure: Application of a new bio-reactance device. Journal of Cardiac Failure 13, 629-636.
Myers J., Gullestad L. (1998) The role of exercise testing and gas-exchange measurement in the prognostic assessment of patients with heart failure. Current Opinion in Cardiology 13, 145-155.
Myers J., Gullestad L., Vagelos R., Do D., Bellin D., Ross H., Fowler M. (1998) Clinical, hemodynamic, and cardiopulmonary exercise test determinants of survival in patients referred for evaluation of heart failure. Annals of Internal Medicine 29, 286-293.
Myers J., Voodi L., Froelicher V.F. (2000) A survey of exercise testing: methods, utilization, interpretation, and safety in the VAHCS. Journal of Cardiopulmonary Rehabilitation 20, 251-258.
Myers J., Wallis J., Lehmann K., Graettinger W., Waibal W., Froelicher V.F. (1991) Hemodynamic determinants of maximal ventilatory oxygen uptake in patients with coronary artery disease. Circulation 84, II-150-.
Myers J., Walsh D., Buchanan N., Froelicher V.F. (1989) Can maximal cardiopulmonary capacity be recognized by a plateau in oxygen uptake?. Chest 96, 1312-1316.
Myers J., Zaheer N., Quaglietti S., Madhavan R., Froelicher V., Heidenreich P. (2006) Association of functional and health status measures in heart failure. Journal of Cardiac Failure 12, 439-445.
Newman D.G., Callister R. (1999) The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review. Aviation. Space, and Environmental Medicine 70, 780-789.
Noakes T.D. (1998) Maximal oxygen uptake: “classical“ versus “contemporary” viewpoints: a rebuttal. Medicine and Science in Sports Exercise 30, 1381-1398.
Pina I.L., Apstein C.S., Balady G.J., Belardinelli R., Chaitman B.R., Duscha B.D., Fletcher B.J., Fleg J.L., Myers J.N., Sullivan M.J. (2003) Exercise and heart failure: A statement from the American Heart Association Committee on Exercise, Rehabilitation, and Prevention. Circulation 107, 1210-1225.
Porszasz J, Caseaburi R, Somfay A, Woodhouse LJ, Whipp BJ. (2003) A treadmill ramp protocol using simultaneous changes in speed and grade. Medicine and Science in Sports and Exercise 35, 1596-1603.
Raval N.Y., Squara P., Cleman M., Yalamanchili K., Winklmaier M., Burkhoff D. (2008) Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. Journal of Clinical Monitoring and Computing 22, 113-119.
Remmen J.J., Aengevaeren W.R., Verheugt F.W., van ver Werf T., Luijten H.E., Bos A., Jansen R.W. (2002) Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output. Clinical Science (Lond) 103, 143-149.
Rowell L.B. (1986) Human Circulation: Regulation During Physical Stress. Circulatory adjustment to dynamic exercise. Rowell LB. Oxford. Oxford University Press.
Squara P., Denjean D., Estagnasie P., Brusset A., Dubois C. (2007) Non-invasive cardiac output monitoring. (NICOM); clinical evaluation. Journal of Intensive Care Medicine 33, 1191-1194.
Sullivan M.J., Knight J.D., Higginbotham M.B., Cobb F.R. (1989) Relation between central and peripheral hemodynamics during exercise in patients with chronic heart failure. Circulation 80, 769-781.
Tamesis B., Stelken A., Byers S., Shaw L., Younis L., Miller D., Chaitman B. (1993) Comparison of the asymptomatic cardiac ischemia pilot and modified asymptomatic cardiac ischemia pilot versus Bruce and Cornell exercise protocols. American Journal Cardiology 72, 715-720.
Thomas J.D., Popovic Z.B. (2006) Assessment of left ventricular function by cardiac ultrasound. Journal of the American College of Cardiology 48, 2012-2025.
Wasserman K., Hansen J.E., Sue D.Y., Casaburi R., Whipp B.J. (2004) Principles of exercise testing and interpretation. Baltimore. Lippincott, Williams & Wilkins.
Williams S.G., Cooke G.A., Wright D.J., Parsons W.J., Riley R.L., Marshall P., Tan L.B. (2001) Peak exercise cardiac power output; a direct indicator of cardiac function strongly predictive of prognosis in chronic heart failure. European Heart Journal 16, 1496-1503.
Williams S.G., Jackson M., Cooke G.A., Barker D., Patwala A., Wright D.J., Albuoaini K., Tan L.B. (2005) How do different indicators of cardiac pump function impact upon the long-term prognosis of patients with chronic heart failure?. American Heart Journal 150, 983-.
Wilmore J.H., Costill D.C. (1999) Physiology of Sports and Exercise. Champaign. Human Kinetics Publishers.
Wilson J.R., Hanamanthu S., Chomsky D.B., Davis S.F. (1999) Relationship between exertional symptoms and functional capacity in patients with heart failure. Journal of the American College of Cardiology 33, 1943-1947.
Wilson J.R., Rayos G., Yeoh T.K., Gothard P. (1995a) Dissociation between peak exercise oxygen consumption and hemodynamic dysfunction in potential heart transplant candidates. Journal of the American College of Cardiology 26, 429-435.
Wilson J.R., Rayos G., Yeoh T.K., Gothard P., Bak K. (1995b) Dissociation between exertional symptoms and circulatory function in patients with heart failure. Circulation 92, 47-53.








Back
|
PDF
|
Share