Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Androit-APP Journal of Sports Science and Medicine
Views
20367
Download
2633
 
©Journal of Sports Science and Medicine (2020) 19, 195 - 203

Review article
Gluteus Maximus Activation during Common Strength and Hypertrophy Exercises: A Systematic Review
Walter Krause Neto1, , Enrico Gori Soares2, Thais Lima Vieira3, Rodolfo Aguiar1, Thiago Andrade Chola1, Vinicius de Lima Sampaio1, Eliane Florencio Gama1  
Author Information
1 Department of Physical Education, Laboratory of Morphoquantitative Studies and Immunohistochemistry, São Judas Tadeu University, São Paulo-SP, Brazil
2 Human Performance Research Group - College of Health Science, Methodist University of Piracicaba (UNIMEP), Piracicaba - São Paulo, Brazil
3 1st Military Fire Brigade Group of the Federal District, Brasilia-DF, Brazil

Walter Krause Neto
✉ Department of Physical Education, Laboratory of Morphoquantitative Studies and Immunohistochemistry, São Judas Tadeu University, São Paulo-SP, Brazil
Email: wild_krause@hotmail.com
Publish Date
Received: 22-08-2019
Accepted: 11-11-2019
Published (online): 24-02-2020
 
ABSTRACT

The gluteus maximus (GMax) is one of the primary hip extensors. Several exercises have been performed by strength and conditioning practitioners aiming to increase GMax strength and size. This systematic review aimed to describe the GMax activation levels during strength exercises that incorporate hip extension and use of external load. A search of the current literature was performed using PubMed/Medline, SportDiscuss, Scopus, Google Scholar, and Science Direct electronic databases. Sixteen articles met the inclusion criteria and reported muscle activation levels as a percentage of a maximal voluntary isometric contraction (MVIC). The exercises classified as very high level of GMax activation (>60% MVIC) were step-up, lateral step-up, diagonal step-up, cross over step-up, hex bar deadlift, rotational barbell hip thrust, traditional barbell hip thrust, American barbell hip thrust, belt squat, split squat, in-line lunge, traditional lunge, pull barbell hip thrust, modified single-leg squat, conventional deadlift, and band hip thrust. We concluded that several exercises could induce very high levels of GMax activation. The step-up exercise and its variations present the highest levels of GMax activation followed by several loaded exercises and its variations, such as deadlifts, hip thrusts, lunges, and squats. The results of this systematic review may assist practitioners in selecting exercised for strengthening GMax.

Key words: Skeletal muscle, gluteus maximus, electromyography, strength training


           Key Points
  • The step-up and its variations may elicit the highest level of Gmax activation possibly to the stabilization requirement of the exercise.
  • Several bilateral exercises (e.g. hip thrusts, squats, deadlifts, and lunges) can provide very high level of GMax activation.
  • The external load, movement velocity, level of fatigue, the mechanical complexity of the exercise, and the need for joint stabilization, might directly influence GMax activation.
  • Further research may investigate the best practices for normalizing GMax activation.

INTRODUCTION

Hip extension is a fundamental movement in daily life and athletic activities. Previous research has proposed an increasing role of hip extensor musculature with heavier lower body exercises (e.g., squats, lunges, and deadlifts) and explosive sports actions (e.g., jumping, sprinting and change of direction) (Beardsley and Contreras, 2014). The primary muscles responsible for this movement are gluteus maximus (GMax), long head of biceps femoris, semimembranosus, semitendinosus, and the ischiocondylar portion of the adductor magnus (Broski et al., 2015; Neumann, 2010; Youdas et al., 2017). Despite the involvement of all these muscles, GMax has been identified as the primary muscle responsible for hip extension, specifically on loaded exercises that typically do not sufficiently activate the hamstrings in tasks involving simultaneous hip and knee extension, such as the squat and the leg press (Krause Neto et al., 2019, McCurdy et al., 2018; Williams et al., 2018; Sugisaki et al., 2014). There is a significant number of studies comparing GMax activation levels between several loaded and bodyweight exercises (Bishop et al., 2018; Boren et al., 2011; Macadam et al., 2015; Macadam and Feser, 2019; Selkowitz et al., 2016).

Electromyography (EMG) is a technique for measuring the electric potential field generated by the depolarization of the sarcolemma (Merletti and Parker, 2004). Despite limitations and common misinterpretations (Vigostky et al., 2015; 2016), under controlled conditions, the EMG signal comprises the summation of motor unit action potentials and provides an index of muscle activation (Enoka and Duchateau, 2015). Therefore, EMG has been widely used to compare the muscle activation between exercises, which can assist the strength and conditioning coach on selecting and systematically progressing exercise intensity (Vigostky et al., 2015, Macadam and Feser, 2019).

Previous studies have systematically reviewed the gluteal muscle activity, measured by EMG, in a variety of lower body exercises (Macadam et al., 2015; Macadam and Feser, 2019). The systematic review conducted by Macadam et al. (2015) showed that exercises with dynamic hip abduction and external rotation elicited high levels of GMax activation (ranging from 79% to 113% of a maximal voluntary isometric contraction [MVIC]). Recently, Macadam and Feser (2019) have found that it is still possible to achieve high levels of GMax activation (>60% of MVIC) by performing exercises with bodyweight as resistance. However, due to the inclusion/exclusion criteria chosen by the authors to answer their research questions, both studies eventually excluded more ecologically valid studies for strength and conditioning coaches that investigated exercises with higher intensity (external load) and neuromuscular demand. As external load may affect exercise mechanics and the resultant muscular activation (Bryanton et al., 2012; Da Silva et al., 2008; Riemann et al., 2012; Swinton et al., 2011), currently there is ambiguity on which exercises that incorporate hip extension and use of external load achieve the most significant Gmax activation.

Several factors, including relative external load, movement velocity, level of fatigue, the mechanical complexity of the exercise (open or closed kinetic chain, weight bearing or non-weight bearing), and the need for joint stabilization, may directly influence GMax activation. The purpose of this systematic review was to describe the GMax activation levels during dynamic exercises that incorporate hip extension and use of external load. To assist strength and conditioning coaches in selecting exercises for the GMax, we categorized the exercises as low level of activation (0 to 20% of MVIC), moderate level of activation (21 to 40% of MVIC), high level of activation (41 to 60% of MVIC), and very high level of activation (greater than 60% of MVIC) accordingly to the recommendations of Macadam and Feser (2019).

METHODS

Literature research strategies

The preferred item declaration guide for systematic review and meta-analysis reports (PRISMA) was used to conduct this systematic review (Liberati et al., 2009).

On February 15th, 2019, a systematic review was conducted using the PubMed/Medline, SportDiscuss, Scopus, Google Scholar, and Science Direct electronic databases. The MeSH descriptors, along with the related terms and keywords, were used as follows: ((((resistance training OR resistance exercise OR training, resistance OR strength training OR training, strength OR weight-lifting strengthening program OR strengthening program, weight-lifting OR strengthening programs, weight-lifting OR weight lifting strengthening program OR weight-lifting strengthening programs OR weight-lifting exercise program OR exercise program, weight-lifting OR exercise programs, weight-lifting OR weight lifting exercise program OR weight-lifting exercise programs OR weight-bearing strengthening program OR strengthening program, weight-bearing OR strengthening programs, weight-bearing OR weight bearing strengthening program OR weight-bearing strengthening programs OR weight-bearing exercise program OR exercise program, weight-bearing OR exercise programs, weight-bearing OR weight bearing exercise program OR weight-bearing exercise programs OR isometric OR exercise OR rehab OR physical therapy OR load OR training))) AND ((muscle development OR development, muscle OR muscular development OR development, muscular OR myogenesis OR myofibrillogenesis OR muscle hypertrophy OR hypertrophy OR hypertrophies OR electromyography OR electromyographies OR surface electromyography OR electromyographies, surface OR electromyography, surface OR surface electromyographies OR electromyogram OR electromyograms OR muscle strength OR power output OR force OR strength OR muscular excitation OR excitation OR EMG OR muscle activation OR activation))) AND ((gluteus maximus OR gluteus OR hip extensor OR hip extensors)).

After reading the titles and abstracts, all eligible full text was assessed for methodological quality using the PEDro methodological quality scale. This scale is composed of eleven questions and scores proportional to the number of items. However, due to the inability to "blind" coaches and practitioners, we excluded three questions, setting the eight as the maximum score. Thus, studies with scores equal to or higher than five were considered of good methodological quality, excluding those with scores equal to or less than 4 (Krause Neto et al., 2019).

Inclusion and exclusion criteria

The inclusion criteria were: (a) original articles; (b) descriptive studies (in case of no raw description of the data, an e-mail was sent to the authors requesting the raw data); (c) studies with physically trained participants; (d) studies that measured surface EMG and reported muscle activation as a percentage of maximal voluntary isometric contraction (MVIC); (e) studies which analyzed the muscle activation of the GMax using strength exercises with external load and (f) English language. Studies with insufficient data, review articles, conference papers, student thesis, samples from metabolic patients, patients with musculoskeletal trauma and older people, poor presentation of data, unclear or vague descriptions of the protocols applied, and articles evaluating isometric, plyometrics, and calisthenics exercises were excluded.

Studies selection

Authors WKN, RA, and TAC independently performed the data analysis with two subsequent meetings to decide on the inclusion of eligible articles in the final text. After each article was read, the following information was extracted: (1) exercise performed, (2) EMG normalization procedure, (3) electrode placement, (4) external load used in the exercise, (5) main findings and (6) mean %MVIC values achieved in each exercise. If two or more studies evaluated the same exercises, the data were pooled as an average of the mean % MVIC of each exercise. Only the mean %MVIC data from each study was used here.

To classify the Gmax activation measured, we used the following levels: 0-20% MVIC, low muscle activation; 21-40% MVIC, moderate muscle activation; 41-60% MVIC, high muscle activation; >60% MVIC, very high muscle activation (Escamilla et al., 2010; Youdas et al., 2014, Cacchio et al., 2008). According to Macadam and Feser (p. 17, 2019), “this classification scheme provides a means by which the practitioner can select exercises, that match the capabilities of their client/athlete thus targeting neuromuscular, endurance, or strength type training, and provides a means by which the GMax can be progressively overloaded in a systematic fashion.”

RESULTS

Search results

A total of 1963 articles were identified in the initial survey. After the analysis of the titles/abstracts, 1853 articles were eliminated, leaving 110 articles selected for full-text examination. After two meetings and discussion of the data, 61 items were included and evaluated by the methodological quality scale and inclusion/exclusion criteria, of which 16 articles were eligible for this systematic review (Figure 1).

In total, 231 participants (90 women and 141 men) underwent 24 strength exercises variations. Table 1 describes the exercises investigated, methods of EMG normalization, testing load, and the main findings. Of these, ten studies investigated the back squat exercise and its variations [partial, parallel and full] (Aspe and Swinton, 2014; Contreras et al., 2015b; 2016a; Da Silva et al., 2017; Evans et al., 2019; Gomes et al., 2015; McCurdy et al., 2018; Williams et al., 2018; Yavuz et al., 2015; Yavuz and Erdag, 2017), five studies investigated the barbell hip thrust and its variations [American and traditional styles and different feet positions] (Andersen et al., 2018; Collazo Garcia et al., 2018; Contreras et al., 2015b; 2016b; Williams et al., 2018), three studies investigated the deadlift, and its variations [traditional and hex bar] (Andersen et al., 2018; Escamilla et al. 2002; McCurdy et al., 2018) and two studies investigated the front squat (Contreras et al., 2016a; Yavuz et al., 2015). Other studies investigated the overhead squat (Aspe and Swinton, 2014), split squat (Williams et al., 2018), modified single-leg squat (McCurdy et al., 2018), belt squat (Evans et al., 2019), lunges (Marchetti et al., 2018), and step-ups (Simenz et al., 2012). External loads were prescribed either by % of 1RM (varied from 40 to 100% of 1RM) or repetition maximum (varied from 3 to 12RM). The methods for normalizing EMG levels varied among the studies; the positions glute squeeze, standing glute squeeze, and prone with 90° flexion being the most common (Table 1). Interestingly, three studies evaluated the lower and upper GMax portions separately (Contreras et al., 2015b; Contreras et al., 2016a; Contreras et al., 2016b).

Although there was no time limit as an inclusion criterion, all the articles included in this review were published between the years of 2002 and 2019. After the methodological quality analysis, all included studies were classified as excellent (mean score 7).

Muscle activation levels

Table 2 describes the pooled average muscle activation levels and the minimum and maximum EMG values for each exercise. In general, the step-up exercise and its variations [lateral, diagonal, and cross-over] showed the highest GMax activation (average 125.09% MVIC, ranging from 104.19-169.22% MVIC).

In Table 3, it is possible to verify that 24 variations related to the ten main exercises included in this study were investigated. In this analysis, the classification of the exercises regarding the activation of GMax ranged from moderate to very high. Among all, the step-up exercise demonstrated the highest Gmax activation. However, possibly due to the wide variation of methods used for EMG normalization, at least 16 exercises variations presented similar maximum Gmax excitatory levels (step-up, lateral step-up, diagonal step-up, crossover step-up, hex bar deadlift, rotation barbell hip thrust, traditional barbell hip thrust, American barbell hip thrust, belt squat, split squat, in-line lunge, traditional lunge, pull barbell hip thrust, modified single-leg squat, band hip thrust and conventional deadlift [Figure 2]).

DISCUSSION

The results of this systematic review have shown that GMax activation varied among the exercises investigated. In general, the step-up exercise and its variations present the highest levels of GMax activation (>100% of MVIC) followed by several loaded exercises and its variations, such as deadlifts, hip thrusts, lunges, and squats, that presented a very high level of GMax activation (>60% of 1RM). It was observed that several factors, including relative external load, movement velocity, level of fatigue, the mechanical complexity of the exercise, and the need for joint stabilization, might directly influence GMax activation.

The exercise that elicited the highest activation levels of the GMax was the step-up and its variations [lateral, diagonal, and cross-over step-up] (Simenz et al., 2012). All four exercises are unilateral and require weight-bearing from the practitioner; therefore, during these exercises, the GMax is responsible for extending the hip joint, while simultaneously maintaining the pelvis level controlling excessive femur adduction and medial rotation (Baker et al., 2014; Blemker and Delp, 2005; Macadam et al., 2015). According to Macadam et al. (2015), the higher excitatory demand for step-up and its variations are associated with the need to stabilize the knees and hip during the upward and downward movement (the more significant synergistic activity of the gluteus medius). However, these exercises are considered difficult to perform and have a high stabilizing demand for most beginning and intermediate practitioners; even for the experienced practitioner, the higher stability demand may limit the load used, and therefore, may hinder maximal strength and hypertrophy development (Behm and Anderson, 2006).

The back squat exercise and its variations are widely used in strength training with goals of increasing strength and lower limb muscle hypertrophy (Clark et al., 2012). This fact was demonstrated here by a large number of studies included, which investigated different variations of the squat (10 articles). In our results, squats were classified as high GMax. However, we found significant variations in the classification between the different types of squats (ranging from low [13% of MVIC] to very high GMax activation [92.7% of MVIC]). Several factors, such as barbell position (front, high/low bar back squat), stance width, and the depth of squat, are the main factors affecting GMax activation during the squat. For example, Paoli et al. (2009) suggested that larger stance widths (1,5 and 2x great trochanter distance) are necessary for greater activation of the GMax during the back squat. Regarding the effect of squat depth on GMax activity, the results are contradicting. Caterisano et al. (2002) compared three different squat depths (partial: ~45° of knee flexion; parallel: ~90° of knee flexion, and full: ~135° of knee flexion) using 100 to 125% of subject’s body weight as external resistance. Their results suggested that the full squat elicited greater GMax activation than the parallel and partial back squat. However, their main limitation was the lack of equalization of external load by the depth investigated. Contreras et al. (2016a) found no significant difference between full and parallel back squats for any of the GMax portions evaluated. More recently, Da Silva et al. (2017) demonstrated that the partial squat elicited higher GMax activation than the full squat variation when external loads are equated to squat depth. GMax relative contribution to hip extensor moment may be reduced in positions of greater squat depth (Vigotsky et al., 2016; Hoy et al., 1990; Neumann, D. A. 2010). Nevertheless, chronic studies have suggested that deeper squats, or a combination of different ranges of motion, induce the most substantial functional and muscular gains, possibly due to more considerable time under tension, mechanical tension, and longer muscle length (Bloomquist et al., 2013; Kubo et al., 2019; Bazyler et al., 2014).

The barbell hip thrust exercise and its variations are expected to demonstrate higher GMax excitation levels when compared to any exercise that includes simultaneous knee and hip flexion/extension movement, such as squats and their variations (Contreras et al., 2015b; Contreras et al., 2016b). Regarding the hip thrust and its variations, GMax activation varied between 49.2 and 105% of MVIC. These results are similar to a recent review performed by our group (Krause Neto et al., 2019), where mean GMax activity ranged between 55 and 105% of MVIC. The foot position is the main factor affecting GMax activation during the barbell hip thrust. For example, Collazo Garcia et al. (2018) compared the GMax activation between the different variations of barbell hip thrust. They observed the highest GMax activation when subjects were oriented to intend to rotate the foot outward. Additionally, Kang et al. (2016) found placing the foot at 30° of hip abduction presented higher GMax activation than 15 and 0° of hip abduction during a bodyweight hip bridge. Another interesting fact is that barbell hip thrusts elicit high and very high GMax activation even when relative low loads are lifted. Collazo Garcia et al. (2018) used 40% of 1RM and obtained high and very high levels of GMax activation in the variations of hip thrusts investigated. Delgado et al. (2019) observed that barbell hip thrust performed at 60 kg (~36% of 1RM) elicited similar GMax activation than Romanian deadlift and back squat at 1RM.

The reader should be aware of the number of methodological limitations present in the studies included in this systematic review: (1) the electrode placement, the EMG signal processing, movement phase analyzed and normalization varied between studies, therefore, may have influenced the results obtained in the systematic review; (2) a heterogeneous sample composed of studies that investigate women and/or men may suffer different influences; (3) the variation of the loads used (40% to 100% maximum) may alter the activity levels of GMax as presented by Yavuz and Erdag (2017); and (4) different levels of training experience and familiarization with the exercises tested may have influenced the EMG levels that were investigated.

CONCLUSION

Despite the limitations of the present review, we observed that several exercises and variations elicited very high levels of GMax activity. Therefore, it is reasonable to suggest that the strength and conditioning coach should select in a variety of exercises, the one that most fit-on clients’ individual needs.

Other factors such as exercise kinetics and kinematics, relative external load, movement velocity, range of motion, level of fatigue, the mechanical complexity of the exercise (open or closed kinetic chain; weight bearing or non-weight bearing) should be considered when selecting an appropriate exercise for strengthening the GMax.

Therefore, this systematic review demonstrated that the step-up exercise and its variations present the highest levels of muscle excitation of GMax followed by several bilateral exercises and its variations, such as deadlifts, hip thrusts, and squats. GMax activity may vary significantly according to changes in technique during the exercise.

ACKNOWLEDGEMENTS

The authors have no conflicts of interest.

AUTHOR BIOGRAPHY

Journal of Sports Science and Medicine Walter Krause Neto
Employment: Personal trainer and Postdoctoral fellow of São Judas Tadeu University.
Degree: PhD
Research interests: Exercise physiology, biomechanics, musculoskeletal disorders, peripheral nervous system morphology, eurodegenerative diseases, aging and strength training adaptations
E-mail: wild_krause@hotmail.com
 

Journal of Sports Science and Medicine Enrico Gori Soares
Employment: Professor
Degree: MSc
Research interests: Biomechanics, strength training and hypertrophy.
E-mail: emaildoenrico@gmail.com
 

Journal of Sports Science and Medicine Thais Lima Vieira
Employment: Personal trainer and military firefighter.
Degree: Bachelor of Physical Education.
Research interests: Exercise physiology and strength training adaptations
E-mail: thapaixao@gmail.com
 

Journal of Sports Science and Medicine Rodolfo Aguiar
Employment: Personal trainer
Degree: Bachelor of Physical Education.
Research interests: Exercise physiology and strength training adaptations
E-mail: rodolfoaguiar4@gmail.com
 

Journal of Sports Science and Medicine Thiago Andrade Chola
Employment: Personal trainer
Degree: Bachelor of Physical Education.
Research interests: Exercise physiology and strength training adaptations
E-mail: thiagochola@gmail.com
 

Journal of Sports Science and Medicine Vinicius de Lima Sampaio
Employment: Personal trainer
Degree: Bachelor of Physical Education.
Research interests: Exercise physiology and strength training adaptations
E-mail: viniciusdls_33@hotmail.com
 

Journal of Sports Science and Medicine Eliane Florencio Gama
Employment: Master's and PhD Advisor at São Judas Tadeu University
Degree: PhD
Research interests: Musculoskeletal disorders, neurodegenerative diseases, morphology/anatomy, body perception/image and strength training adaptations
E-mail: efgama@profaeliane.net
 
 
REFERENCES
Journal of Sports Science and Medicine Andersen L.L., Magnusson S.P., Nielsen M., Haleem J., Poulsen K., Aagaard P. (2006) Neuromuscular activation in conventional therapeutic exercises and heavy resistance exercises: implications for rehabilitation. Physical Therapy 86, 683-697.
Journal of Sports Science and Medicine Andersen V., Fimland M. S., Mo D. A., Iversen V.M., Vederhus T., Rockland Hellebø L.R., Nordaune K.I., Saeterbakken A.H. (2018) Electromyographic Comparison of Barbell Deadlift, Hex Bar Deadlift, and Hip Thrust Exercises: A Cross-Over Study. Journal of Strength and Conditioning Research 32, 587-593.
Journal of Sports Science and Medicine Aspe R.R., Swinton P.A. (2014) Electromyographic and kinetic comparison of the back squat and overhead squat. Journal of Strength and Conditioning Research 28, 2827-36.
Journal of Sports Science and Medicine Baker P. J., Hapuarachchi K. S., Ross J. A., Sambaiew E., Ranger T. A., Briggs C. A. (2014) Anatomy and biomechanics of gluteus maximus and the thoracolumbar fascia at the sacroiliac joint. Clinical Anatomy 27, 234-240.
Journal of Sports Science and Medicine Bazyler C. D., Sato K., Wassinger C. A., Lamont H. S., Stone M. H. (2014) The efficacy of incorporating partial squats in maximal strength training. Journal of Strength and Conditioning Research 28, 3024-3032.
Journal of Sports Science and Medicine Beardsley C., Contreras B. (2014) The increasing role of the hip extensor musculature with heavier compound lower-body movements and more explosive sports actions. Journal of Strength and Conditioning Research 36, 49-55.
Journal of Sports Science and Medicine Behm D. G., Anderson K. G. (2006) The role of instability with resistance training. Journal of Strength and Conditioning Research 20, 716-722.
Journal of Sports Science and Medicine Bishop B.N., Greenstein J., Etnoyer-Slaski J.L., Sterling H., Topp R. (2018) Electromyographic analysis of gluteus maximus, gluteus medius, and tensor fascia latae during therapeutic exercises with and without elastic resistance. International Journal of Sports Physical Therapy 13, 668-675.
Journal of Sports Science and Medicine Blemker S. S., Delp S. L. (2005) Three-dimensional representation of complex muscle architectures and geometries. Annals of Biomedical Engineering 33, 661-373.
Journal of Sports Science and Medicine Bloomquist K., Langberg H., Karlsen S., Madsgaard S., Boesen M., Raastad T. (2013) Effect of range of motion in heavy load squatting on muscle and tendon adaptations. European Journal of Applied Physiology 113, 2133-42.
Journal of Sports Science and Medicine Boren K., Conrey C., Le Coguic J., Paprocki L., Voight M., Robinson T.K. (2011) Electromyographic analysis of gluteus medius and gluteus maximus during rehabilitation exercises. International Journal of Sports Physical Therapy 6, 206-23.
Journal of Sports Science and Medicine Broski S. M., Murthy N. S., Krych A. J., Obey M. R., Collins M. S. (2015) The adductor magnus “mini-hamstring”: MRI appearance and potential pitfalls. Skeletal Radiology 45, 213-219.
Journal of Sports Science and Medicine Bryanton M. A., Kennedy M. D., Carey J. P., Chiu L. Z. (2012) Effect of squat depth and barbell load on relative muscular effort in squatting. Journal of Strength and Conditioning Research 26, 2820-2828.
Journal of Sports Science and Medicine Cacchio A., Don R., Ranavolo A., Guerra E., McCaw S. T., Procaccianti R., Camerota F., Frascarelli M., Santilli V. (2008) Effects of 8-week strength training with two models of chest press machines on muscular activity pattern and strength. Journal of Electromyography and Kinesiology 18, 618-627.
Journal of Sports Science and Medicine Caterisano A., Moss R.F., Pellinger T.K., Woodruff K., Lewis V.C., Booth W., Khadra T. (2002) The effect of back squat depth on the EMG activity of 4 superficial hip and thigh muscles. Journal of Strength and Conditioning Research 16, 428-32.
Journal of Sports Science and Medicine Clark D.R., Lambert M.I., Hunter A.M. (2012) Muscle activation in the loaded free barbell squat: a brief review. Journal of Strength and Conditioning Research 26, 1169-78.
Journal of Sports Science and Medicine Collazo García C.L., Rueda J., Suárez Luginick B., Navarro E. (2018) Differences in the Electromyographic Activity of Lower-Body Muscles in Hip Thrust Variations. Journal of Strength and Conditioning Research. press.
Journal of Sports Science and Medicine Contreras B., Vigotsky A.D., Schoenfeld B.J., Beardsley C., Cronin J. (2015a) A comparison of two gluteus maximus EMG maximum voluntary isometric contraction positions. PeerJ 3, e1261.
Journal of Sports Science and Medicine Contreras B., Vigotsky A.D., Schoenfeld B.J., Beardsley C., Cronin J. (2015b) A Comparison of Gluteus Maximus, Biceps Femoris, and Vastus Lateralis Electromyographic Activity in the Back Squat and Barbell Hip Thrust Exercises. Journal of Applied Biomechanics 31, 452-8.
Journal of Sports Science and Medicine Contreras B., Vigotsky A.D., Schoenfeld B.J., Beardsley C., Cronin J. (2016a) A Comparison of Gluteus Maximus, Biceps Femoris, and Vastus Lateralis Electromyography Amplitude in the Parallel, Full, and Front Squat Variations in Resistance-Trained Females. Journal of Applied Biomechanics 32, 16-22.
Journal of Sports Science and Medicine Contreras B., Vigotsky A.D., Schoenfeld B.J., Beardsley C., Cronin J. (2016b) A Comparison of Gluteus Maximus, Biceps Femoris, and Vastus Lateralis Electromyography Amplitude for the Barbell, Band, and American Hip Thrust Variations. Journal of Applied Biomechanics 32, 254-260.
Journal of Sports Science and Medicine Da Silva E.M., Brentano M.A., Cadore E.L., De Almeida A.P., Kruel L.F. (2008) Analysis of muscle activation during different leg press exercises at submaximum effort levels. Journal of Strength and Conditioning Research 22, 1059-1065.
Journal of Sports Science and Medicine Da Silva J.J., Schoenfeld B.J., Marchetti P.N., Pecoraro S.L., Greve J.M.D., Marchetti P.H. (2017) Muscle Activation Differs Between Partial and Full Back Squat Exercise With External Load Equated. Journal of Strength and Conditioning Research 31, 1688-1693.
Journal of Sports Science and Medicine De Ridder E.M., Van Oosterwijck J.O., Vleeming A., Vanderstraeten G.G., Danneels L.A. (2013) Posterior muscle chain activity during various extension exercises: an observational study. BMC Musculoskeletal Disorders 9, 204.
Journal of Sports Science and Medicine Delgado J., Drinkwater E.J., Banyard H.G., Haff G.G., Nosaka K. (2019) Comparison Between Back Squat, Romanian Deadlift, and Barbell Hip Thrust for Leg and Hip Muscle Activities During Hip Extension. Journal of Strength and Conditioning Research 33, 2595-2601.
Journal of Sports Science and Medicine Enoka RM, Duchateau J. (2015) Inappropriate interpretation of surface EMG signals and muscle fiber characteristics impedes understanding of the control of neuromuscular function. Journal of Applied Physiology 119, 1516-1518.
Journal of Sports Science and Medicine Escamilla R.F., Francisco A.C., Kayes A.V., Speer K.P., Moorman C.T. (2002) An electromyographic analysis of sumo and conventional style deadlifts. Medicine and Science of Sports Exercise 34, 682-8.
Journal of Sports Science and Medicine Escamilla R.F., Lewis C., Bell D., Bramblet G., Daffron J., Lambert S., Pecson A., Imamura R., Paulos L., Andrews J.R. (2010) Core muscle activation during Swiss ball and traditional abdominal exercises. Journal of Orthopaedic & Sports Physical Therapy 40, 265-276.
Journal of Sports Science and Medicine Evans T.W., McLester C.N., Howard J.H., McLester J.R., Calloway JP. (2019) A comparison of muscle activation between back squats and belt squats. Journal of Strength and Conditioning Research 33, S52-S59.
Journal of Sports Science and Medicine Gomes W.A., Brown L.E., Soares E.G., da Silva J.J., de O Silva F.H., Serpa É.P., Corrêa D.A., Vilela Junior, Gde. B., Lopes C.R., Marchetti P.H. (2015) Kinematic and sEMG analysis of the back squat at different intensities with and without knee wraps. Journal of Strength and Conditioning Research 29, 2482-2487.
Journal of Sports Science and Medicine Haff, G. G., and Triplett, N. T. (2015) Essentials of strength training and conditioning. 4th edition. Human kinetics.
Journal of Sports Science and Medicine Hoy M. G., Zajac F. E., Gordon M. E. (1990) A musculoskeletal model of the human lower extremity: the effect of muscle, tendon, and moment arm on the moment-angle relationship of musculotendon actuators at the hip, knee, and ankle. Journal of biomechanics 23, 157-169.
Journal of Sports Science and Medicine Kang S., Choung S., Jeon H. (2016) Modifying the hip abduction angle during bridging exercise can facilitate gluteus maximus activity. Manual Therapy 22, 211-215.
Journal of Sports Science and Medicine Korak J.A., Paquette M.R., Fuller D.K., Caputo J.L., Coons J.M. (2018) Muscle Activation Patterns of Lower-Body Musculature Among 3 Traditional Lower-Body Exercises in Trained Women. Journal of Strength and Conditioning Research 32, 2770-2775.
Journal of Sports Science and Medicine Krause Neto W., Vieira T.L., Gama E.F. (2019) Barbell Hip Thrust, Muscular Activation and Performance: A Systematic Review. Journal of Sports Science and Medicine 18, 198-206.
Journal of Sports Science and Medicine Kubo K., Ikebukuro T., Yata H. (2019) Effects of squat training with different depths on lower limb muscle volumes. European Journal of Applied Physiology 119, 1933-1942.
Journal of Sports Science and Medicine Lasevicius T., Ugrinowitsch C., Schoenfeld B.J., Roschel H., Tavares L.D., De Souza E.O., Laurentino G., Tricoli V. (2018) Effects of different intensities of resistance training with equated volume load on muscle strength and hypertrophy. European Journal of Sports Science 18, 772-780.
Journal of Sports Science and Medicine Lee S., Schultz J., Timgren J., Staelgraeve K., Miller M., Liu Y. (2018) An electromyographic and kinetic comparison of conventional and Romanian deadlifts. Journal of Exercise Science & Fitness 16, 87-93.
Journal of Sports Science and Medicine Liberati A., Altman D.G., Tetzlaff J., Mulrow C., Gotzsche P.C., Ioannidis J.P., Clarke M., Devereaux P.J., Kleijnen J., Moher D. (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. PLoS Medicine 6, e1000100.
Journal of Sports Science and Medicine Macadam P., Cronin J., Contreras B. (2015) An examination of the gluteal muscle activity associated with dynamic hip abduction and hip external rotation exercise: A systematic review. International Journal of Sports Physical Therapy 10, 573.
Journal of Sports Science and Medicine Macadam P., Feser E.H. (2019) Examination of gluteus maximus electromyographic excitation associated with dynamic hip extension during body weight exercise: a systematic review. International Journal of Sports Physical Therapy 14, 14-31.
Journal of Sports Science and Medicine Marchetti P.H., Guiselini M.A., da Silva J.J., Tucker R., Behm D.G., Brown L.E. (2018) Balance and Lower Limb Muscle Activation between In-Line and Traditional Lunge Exercises. Journal of Human Kinetics 13, 15-22.
Journal of Sports Science and Medicine McCurdy K., Walker J., Yuen D. (2018) Gluteus Maximus and Hamstring Activation During Selected Weight-Bearing Resistance Exercises. Journal of Strength and Conditioning Research 32, 594-601.
Journal of Sports Science and Medicine Merletti, R. and Parker, P. A. (2004) Electromyography: physiology, engineering, and non-invasive applications. Vol. 11. John Wiley & Sons.
Journal of Sports Science and Medicine Neumann D.A. (2010) Kinesiology of the hip: a focus on muscular actions. Journal of Orthopaedic & Sports Physical Therapy 40, 82-94.
Journal of Sports Science and Medicine Paoli A., Marcolin G., Petrone N. (2009) The effect of stance width on the electromyographical activity of eight superficial thigh muscles during back squat with different bar loads. Journal of Strength and Conditioning Research 23, 246-250.
Journal of Sports Science and Medicine Ramis T.R., Muller C.H.L., Boeno F.P., Teixeira B.C., Rech A., Pompermayer M.G., Medeiros N.D.S., Oliveira Á.R., Pinto R.S., Ribeiro J.L. (2018) Effects of traditional and vascular restricted strength training program with equalized volume on isometric and dynamic strength, muscle thickness, electromyographic activity, and endothelial function adaptations in young adults. Journal of Strength and Conditioning Research , 30.
Journal of Sports Science and Medicine Riemann B.L., Lapinski S., Smith L., Davies. G. (2012) Biomechanical analysis of the anterior lunge during 4 external-load conditions. Journal of Athletic Training 47, 372-378.
Journal of Sports Science and Medicine Schoenfeld B.J., Contreras B., Vigotsky A.D., Peterson M. (2016) Differential effects of heavy versus moderate loads on measures of strength and hypertrophy in resistance-trained men. Journal of Sports Science and Medicine 15, 715-722.
Journal of Sports Science and Medicine Selkowitz D.M., Beneck G.J., Powers C.M. (2016) Comparison of electromyographic activity of the superior and inferior portions of the gluteus maximus muscle during common therapeutic exercises. Journal of Orthopaedic & Sports Physical Therapy 46, 794-9.
Journal of Sports Science and Medicine Simenz C.J., Garceau L.R., Lutsch B.N., Suchomel T.J., Ebben W.P. (2012) Electromyographical analysis of lower extremity muscle activation during variations of the loaded step-up exercise. Journal of Strength and Conditioning Research 26, 3398-405.
Journal of Sports Science and Medicine Stragier S., Baudry S., Carpentier A., Duchateau J. (2019) Efficacy of a new strength training design: the 3/7 method. European Journal of Applied Physiology 119, 1093-1104.
Journal of Sports Science and Medicine Sugisaki N., Kurokawa S., Okada J., Kanehisa H. (2014) Difference in the recruitment of hip and knee muscles between back squat and plyometric squat jump. PLoS ONE 9, e101203.
Journal of Sports Science and Medicine Swinton P. A., Stewart A., Agouris I., Keogh J. W., Lloyd R. (2011) A biomechanical analysis of straight and hexagonal barbell deadlifts using submaximal loads. Journal of Strength and Conditioning Research 25, 2000-2009.
Journal of Sports Science and Medicine Vigotsky A.D., Beardsley C., Contreras B., Steele J., Ogborn D., Phillips S.M. (2015) Greater Electromyographic Responses Do Not Imply Greater Motor Unit Recruitment and ‘Hypertrophic Potential’ Cannot Be Inferred. Journal of Strength and Conditioning Research 31, e1-e4.
Journal of Sports Science and Medicine Vigotsky A.D., Halperin I., Lehman G.J., Trajano G.S., Vieira T.M. (2018) Interpreting Signal Amplitudes in Surface Electromyography Studies in Sport and Rehabilitation Sciences. Frontiers in Physiology 4, 985.
Journal of Sports Science and Medicine Vigotsky A.D., Ogborn D., Phillips S.M. (2016) Motor unit recruitment cannot be inferred from surface EMG amplitude and basic reporting standards must be adhered to. European Journal of Applied Physiology 116, 657-8.
Journal of Sports Science and Medicine Wakahara T., Fukutani A., Kawakami Y., Yanai T. (2013) Nonuniform muscle hypertrophy: its relation to muscle activation in training session. Medicine and Science of Sports and Exercise 45, 2158-2165.
Journal of Sports Science and Medicine Williams M.J., Gibson N., Sorbie G.G., Ugbolue U.C., Brouner J., Easton C. (2018) Activation of the gluteus maximus during performance of the back squat, split squat, and barbell hip thrust and the relationship with maximal sprinting. Journal of Strength and Conditioning Research 9, 309.
Journal of Sports Science and Medicine Yavuz H.U., Erdag D. (2017) Kinematic and electromyographic activity changes during back squat with submaximal and maximal loading. Applied Bionics Biomechanics , 9084725.
Journal of Sports Science and Medicine Yavuz H.U., Erdağ D., Amca A.M., Aritan S. (2015) Kinematic and EMG activities during front and back squat variations in maximum loads. Journal of Sports Science 33, 1058-66.
Journal of Sports Science and Medicine Youdas J.W., Adams K.E., Bertucci J.E., Brooks K.J., Nelson M.M., Hollman J.H. (2014) Muscle activation levels of the gluteus maximus and medius during standing hip-joint-strengthening exercises using elastic-tubing resistance. Journal of Sports Rehabilitation 23, 1-11.
Journal of Sports Science and Medicine Youdas J.W., Hartman J.P., Murphy B.A., Rundle A.M., Ugorowski J.M., Hollman J.H. (2017) Electromyographic analysis of gluteus maximus and hamstring activity during the supine resisted hip extension exercise versus supine unilateral bridge to neutral. Physiotherapy: Theory and Practice 33, 124-130.
 
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.